Follow Infotel Systems on Facebook Follow Infotel Systems on twitter

Status LED's For Carrier Access Adit 600 - TDM Voice

Carrier Access Adit 600 - TDM Voice
On the Adit, Anything Red is an Issue

Possible Failures

Light
Status
Action to take
T1-1 SOLID RED T1 is down. Call the carrier.
MAJOR/MINOR SOLID RED T1 could have taken a power surge. Call the carrier.
CRD NOT SOLID GREEN Voice over IP card failure. Call the carrier.

TDM Controller - This is the T1 Card.

Light
Status
Description
MAJOR OR MINOR OFF No alarms present
RED / YELLOW Red = Major alarm       Yellow = Minor alarm
LOCAL OFF Remote mode (DIP switches disabled)
GREEN Local mode (DIP switches enabled)
ACO OFF Normal mode.  No alarms are being suppressed.
YELLOW Alarm cutoff active. One or more active alarms suppressed.
T1-1 OR T1-2 OFF Off line
GREEN Normal
RED Loss of Signal (LOS) detected
YELLOW Bipolar Violation (BPV) detected
FLASHING GREEN Loopback active
FLASHING RED Loss of Frame (LOF) or Alarm Indication Signal (AIS) detected
FLASHING YELLOW Yellow alarm (Remote Alarm Indication) detected.

Router

Light
Status
Description
CRD Off Loss of power
Green No current alarms
Red Alarm state active. See alarm log for cause
Red Flashing Self-test or Boot in-process
Yellow Flashing Card is saving data to flash RAM, do not power down
LNK Off No Ethernet link
Green Good Ethernet link
10/100 Off 10 Mb Ethernet
Green 100 Mb Ethernet
TX/RX Off No Ethernet transmit activity
Green Current Ethernet TX/RX activity
Yellow Current Ethernet TX/RX collision

For more information or to have your device listed please contact Infotel Systems Inc

The story Behind "Status Lights"

Infotel Systems . 6008 Hermitage Rd . Richmond, Virginia 23228 . Phone: 804-266-6688 . Fax: 804-266-6611 Contact Us