Status LED's For - Cisco 1700 Series

Cisco 1700 Series

Normal LED Indications

Light
Status
Action to take
PWR Solid Green Power is being supplied to the router
OK Solid Green The router software is loaded and functional
ETH ACT Flashing Green here is network traffic on the Ethernet connections

Normal LED Indications (BACK)

Light
Status
DESCRIPTION
LNK Solid Green When the LED is on, the router is connected to your local Ethernet network through the ETHERNET 10BASET port
CARRIER Solid Green On means that the cable is correctly connected and the router can communicate across the WAN
ALARM LIT if CARRIER is green and ALARM is lit, you are getting either framed or unframed all ones, more than likely. This is either a problem with the carrier not cross connecting your circuit to something useful, or equally likely, a problem with the TX pair going between you and the smartjack (checking the smartjack for a local alarm would tell you the difference)
LOOPBACK LIT  your circuit is in loopback. You can typically clear this loopback by powercycling the equipment or hitting the loopback button on the WIC with an inkpen. (If you just reported an issue, your carrier may be testing your circuit, and you don't want to do this)
FLASH PC CARD Solid Green On means that the Flash PC card is correctly installed