Various Status Lights - Kentrox Tsmart CSU

Normal
Status Lights

 
Network Down
Status Lights *
 
Call carrier

 

 
Terminal Down
Status Lights
 
Call vendor

 

* Transmit to carrier pair cut has these changes to picture: LOS = dark  AIS = solid red 

 

 

 Light
 Status

PWR/FAIL

Green Powered and operational

Red Powered but not fully operational

TA/FEL

Yellow Solid - Set or Test code sent to far end or local unit is in loop back

Yellow Flash - Far end loop back has been verified

NET LP

Yellow Network Loop Back (TLB or LLB) set

SEND

Yellow Sending loop back or test code

ACO

Green Alarm Cut-Off switch is operating. Remains on until the alarm condition is removed or until another alarm occurs

LOC LP

Yellow Local Loop Back in process

CODE

Yellow Any code being received

DATA

Green Valid data is present at the Network or Terminal Interface Off Data stream interrupted

BPV

 Red Bipolar Violation (BPV) received (flashes) When B8ZS is enabled, LED doesn’t light on BPVs that are part of B8ZS pattern

AIS

 Red Alarm Indication Signal received for one second

LOS

 Red Loss of Signal received

KA

 Red Keep-Alive signal transmitted toward Network

PD

 Red Pulse Density below 1 in 8 detected in the outgoing network signal.

YEL

 Yellow Yellow Alarm code received

OOF

 Red Out Of Frame condition 

EER

 Red Error rate exceeds selected threshold

NI (Network)

(carrier)

 Red Specifies LOS, YEL, AIS, EER, OOF, BPV, or CODE is on NI signal

TI (Terminal)

(Vendor)

Red Specifies LOS, PD, YEL, AIS, EER,

OOF, BPV, or CODE is on TI signal